Showing 6 Verified Switchgear Protection Products
IEC 60947-2 IEC 61557-12 ISO9001 Certified OEM / ODM Available
Fixed Frame Intelligent Universal Circuit Breaker Fixed Type Frame Air Circuit Breaker

Intelligent Universal Circuit Breaker Fixed Type Frame ACB

$401.82 - $408.63 / Piece MOQ: 1 pc
Mounting StyleStationary / Bolted Fixed Type
Rated VoltageAC 400V / 690V (50/60 Hz)
Protection UnitMicroprocessor Intelligent Controller
Reference StandardIEC 60947-2 / EN 60947-2
Draw-Out Cradle Universal Electrical ACB Draw Out Type Circuit Breaker

Universal Electrical ACB Draw-Out Type Air Circuit Breaker

$401.82 - $408.63 / Piece MOQ: 1 pc
Mounting StyleDraw-Out with Racking Mechanism
Maintenance BenefitRapid Replacement Without Power Cut
Interlocking ModeMechanical & Key Padlock Safety
Safety IsolationAutomatic Disconnecting Shutters
Medium Voltage ZN63 VS1 12KV Three Phase Vacuum Circuit Breaker

ZN63(VS1)-22 12KV Indoor Vacuum Circuit Breaker

$600.00 - $700.00 / Piece MOQ: 10 pcs
Rated Voltage12kV – 22kV Distribution Grid
Arc QuenchingHigh-Vacuum Sealed Bottle
Operating ClassM2 Mechanical Endurance Class
Target FacilitySubstations, Primary Feeder Panels
Multi-Function Three-phase Multi-functional Meter Digital Display

Three-Phase Multi-Functional Digital Energy Meter

$10.99 - $12.80 / Piece MOQ: 5 pcs
Measured ParametersCurrent (A), Voltage (V), kW, Frequency
Display InterfaceWide-Angle Backlit Digital LCD
Accuracy RatingClass 0.5S / Class 1.0
IntegrationFits Switchgear Instrument Doors
Power Sub-Meter Intelligent Three-Phase Power Sub-Meter with LED Display

Intelligent 3-Phase Sub-Meter with LED Display

$8.99 - $9.99 / Piece MOQ: 10 pcs
Panel Frame Dimensions96×96 / 72×72 / 80×80 mm Options
Signal InputDirect / CT Connected (AC/DC Dual)
Installation MethodFlush Door Mount with Retaining Clips
Operating Temp-25°C to +55°C Industrial Enclosures
RS485 Modbus Three-Phase Energy Meter with Harmonic Measurement and RS485

Energy Meter with Harmonic Analysis & RS485

$11.50 - $12.90 / Piece MOQ: 5 pcs
Harmonics AnalysisTotal & Individual up to 31st Harmonic
Communication PortRS-485 Serial (Modbus-RTU Standard)
Power AnalyticsActive, Reactive, Apparent kWh & PF
SCADA ReadinessCompatible with PLC & Energy EMS

Engineering Guide: Draw-Out vs. Fixed Type Air Circuit Breaker

When building low-voltage main distribution panels (PCC) or motor control centres (MCC), selecting the right ACB framework determines maintenance cost, switchboard uptime, and initial procurement budget. Zhejiang Graybar Electric Co., Ltd. manufactures both variants according to IEC 60947-2.

Technical Parameter Draw-Out Type ACB Fixed Type ACB
Installation Architecture Breaker body sits inside a dedicated cradle connected via sliding primary finger clusters. Directly bolted to copper busbars with fixed terminal extensions.
Downtime During Service Zero line shutdown needed; racked out within 3 minutes for contact inspection. Requires de-energising upstream transformer or sub-station busbar.
Visual Isolation Safety Integrated mechanical shutters isolate live copper stabs automatically. Requires separate upstream disconnector switch for visible break.
Optimal Use Case Hospitals, Tier 3/4 Data Centers, continuous chemical plants, airports. Standard commercial complexes, compact standalone pump stations.
Procurement Quality Standards

Factory Rigorous Testing & B2B Guarantees

Each Air Circuit Breaker leaving the Zhejiang Graybar Electric Co., Ltd. facility in Liushi undergoes complete secondary injection testing, microcomputer controller trip response calibration, and 2,500V power frequency dielectric withstand verification. Importers and switchboard builders are provided with complete batch factory test reports, dimensional CAD drawings for copper busbar punching, and wiring schematics for shunt release and motor-operated charging mechanisms.

Need Custom Rated Current or Auxiliary Switch Configurations?

Send your switchgear project single-line diagram (SLD) or BOM list to [email protected].