4P 63A Single Phase Manual Changeover Switch with Breaker ATS
- Rated Current63A
- Poles4-Pole Isolation
- StandardIEC 60947-6-1
- ApplicationResidential & Commercial
Precision-manufactured at our Liushi production facility, our molded case circuit breakers and automatic transfer units deliver reliable breaking capacities, thermal endurance, and precise selective coordination for Riyadh’s demanding electrical installations.
Deploying low-voltage electrical apparatus in the Central Province of Saudi Arabia requires engineering accommodations that go far beyond temperate-zone standards. From massive summer ambient thermal loads to particulate ingestion, our MCCBs are tailored to overcome regional grid stressors.
Riyadh outdoor switchgear and rooftop package substations regularly experience interior enclosure temperatures exceeding 60°C. Standard thermal-magnetic breakers encounter premature nuisance tripping under these conditions. Our microprocessor-based Electronic Trip Units (ETU) utilize digital temperature compensation and precision current transformers, maintaining calibration curves across 0°C to +55°C without arbitrary over-sizing.
During the Khamaseen dust storm seasons, airborne silica dust penetrates low-voltage motor control centers (MCCs) across industrial areas like Sudair and Al-Kharj. Graybar molded case shells are pressed from high-grade Bulk Molding Compound (BMC) with tight internal gasket paths, preventing conductive silicate bridging between phase barriers and protecting internal linkages from binding.
Projects such as the New Murabba, Qiddiya, and Diriyah Gate demand compact form factors with severe breaking capacity (Icu ≥ 65kA at 400/415V). Our 125A–250A and 630A frame MCCBs provide cascade and discrimination ratings that prevent upstream blackouts, isolating localized feeder short-circuits in commercial HVAC chiller banks and high-density office zones.
Strategic investments in industrial automation, renewable integration, and hyper-scale data hubs are permanently transforming how Riyadh panel builders, mechanical-electrical consultants, and procurement managers source switchgear.
Riyadh commercial infrastructure is abandoning non-communicative thermal breakers. National developments require cloud-interfaced BMS platforms. Graybar electronic MCCBs feature integrated micro-controllers and RS485 Modbus RTU communication channels, measuring real-time phase voltage, active power, harmonics, and breaker contact wear, reducing maintenance downtime by over 35%.
While historical residential sections in Riyadh historically used 127/220V networks, SASO’s aggressive standardization to the 230/400V 50/60Hz system has completed. Modern distribution boards demand 4-pole circuit breakers equipped to safely break the neutral wire, containing harmonic triple currents caused by widespread variable-frequency drive (VFD) air conditioning.
Riyadh's emergence as the Middle East cloud corridor has created unprecedented demand for Class PC Automatic Transfer Switches (ATS) coupled with electronic MCCBs. By eliminating moving gear mechanisms in trip units and maintaining short-circuit withstand values (Icw) for up to 30ms, downstream PDU racks remain protected from system-wide voltage sags.
| Circuit Protection Type | Rated Current (In) | Icu / Ics Breaking Range | Saudi Grid Positioning | Engineering Specification Note |
|---|---|---|---|---|
| Electronic Trip MCCB | 100A – 630A | 50kA / 70kA / 100kA | Secondary Sub-Distribution / HVAC Centers | Digital LSI trip adjustments; eliminates thermal de-rating up to 55°C. |
| Thermal-Magnetic MCCB | 16A – 250A | 35kA / 50kA | Branch Feeders, Machine Protection | Ag-W-C silver alloy contacts; ideal for resistive loads and motor control. |
| Automatic Transfer Switch (ATS) | 63A – 125A | 10kA – 35kA Withstand | Utility-to-Genset Emergency Power | Microprocessor-governed double-throw mechanism; transfer cycle < 50ms. |
| Intelligent ACB (Draw-out) | 630A – 3200A | 65kA – 100kA | Main Incomers, 13.8kV/400V Substation Outgoing | Rack-in cradle allows inspection without isolating the main copper busbar. |
| Surge Protective Device (SPD) | 20kA – 80kA (Imax) | Up < 1.8kV | Main Distribution Boards (Class I/II) | High-energy ZnO varistor to mitigate dry-desert electrostatic and lightning surges. |
Operating from Huangyu Village, Liushi Town, Wenzhou—the globally recognized epicenter of low-voltage electrical manufacturing—we integrate raw material moulding, contact metallurgy, and robotic robotic assembly under a single stringent quality umbrella.
Our moving and stationary contacts feature high-purity silver-tungsten-carbide (Ag-W-C) sintering, providing superior arc suppression and zero contact welding even under full 100kA fault clearing cycles.
Every individual circuit breaker undergoes computerized instantaneous short-circuit impulse tests, thermal calibration, and 2,500V dielectric insulation verification prior to final seaworthy boxing.
We eliminate unreasonable entry barriers for Saudi contractors and panel shops. Trial orders start from an accessible 5-piece MOQ for MCCBs and 1 piece for heavy air circuit breakers (ACB).
Custom laser-marked brandings, bespoke breaking capacities, custom neutral configurations, and complete test documentation mapped against SASO and IEC 60947 series requirements.
Critical technical and logistical clarifications to simplify your import verification and equipment commissioning.
All our low-voltage circuit breakers are designed and type-tested in alignment with IEC 60947-2 (industrial) and IEC 60898-1 (commercial/residential) standards. We provide third-party laboratory test reports, CB scheme certificates, and factory conformity declarations necessary to generate the Product Certificate of Conformity (PCoC) and Shipment Certificate of Conformity (SCoC) via the official SABER platform for direct customs entry through Riyadh Dry Port or King Abdulaziz Port Dammam.
Thermal-magnetic circuit breakers rely on physical bimetallic deflection that is affected by ambient heat inside sealed metal enclosures. When ambient temperatures inside a switchboard hit 50°C–55°C during Riyadh's summer, traditional breakers trip below their rated current. Electronic MCCBs measure the actual RMS current electronically using internal current transformers, completely mitigating environmental temperature bias and offering dial-adjustable overload (Ir) and short-time pickup (Isd) settings.
Yes. In Saudi installations utilizing TN-S or TT grounding topologies—particularly commercial buildings with severe non-linear loads like datacenter switches, LED drivers, and variable-frequency drives—neutral harmonic currents can rival phase currents. We supply 4P MCCBs with 100% neutral current breaking capacity (or adjustable 50%/100% neutral protection) to isolate both line and neutral conductors safely during fault maintenance.
Standard frame MCCB orders under 500 units are manufactured, serialized, and packed within 10 to 15 working days. Consolidations leave directly from Ningbo or Shanghai port, taking approximately 18 to 24 days maritime transit to Jeddah Islamic Port or King Abdulaziz Port in Dammam, with direct inland bonded trucking transit up to Riyadh.
Connect directly with our engineering sales team in Liushi. Share your panel board schedules, bill of materials (BOM), or project single-line diagrams (SLD) for an immediate technical compliance check and customized price quote.
Contact Us